[2025 Upgraded] BlueStars 108-130 uf/MFD 220-250 VAC ±20% CD60 Volts Round Start Capacitor 50/60 Hz AC Electric Replacement Part - Exact Fit for Single-Phase Electric Motors

  • WHAT YOU GET - 108-130 uf/MFD 220-250 VAC Volts Round Start Capacitor 50/60 Hz AC Electric
  • SPECIFICATIONS - Capacitance: 108-130 uf; Rated voltage: AC 220-250V; Tolerance: +/-20%; Shape: Round Motor Start; Capacitor dimensions: 36mm x 70mm; Operating temperature range: -40 to +65/ -40 to 149; No PCBs. Engineered for safety 10000 AFC anti explosion pressure switch
  • REPLACEMENT FOR - 840532010630, Aerovox 108-130, Dayton Grainger 2MEL8 Aero PSU10830, MARS 11063, JARD 11963, Global 1063, Trane/ Service First CPT00162, CPT0162, CPT-0162, Packard PRMJ108 PRMJ108A, Supco CS108X330, CS108-130X330, NTE MSC330V108, 620288 and other Start Capacitors with this uF/Mfd & VAC Rating
  • PREMIUM QUALITY: Compliant with the TOUGHEST US and Australian Standards for AC motor run capacitors, including UL & CUL, CEL and TÜV SÜD
  • EASY APPLICATION - Starting capacitors can be used for various purposes, such as air conditioning, pool pump capacitors, water pumps, table saws, general motors, and ordinary motors.
  • 100% LIFETIME PROTECTION: Enjoy reliable performance with our lifetime protection, ensuring that your product will always be covered for any defects or issues that may arise.
Overview
Specs
Reviews
1

Perfect fit

Universal fit with any brands with the same ratings

2

Premium quality

This product adopts a high-quality metalized polypropylene film that provides stable and durable performance

3

Saving solution

Enjoy the great feeling when your engine is repaired and works properly like before - BlueStars brings DIY solutions to help you deal with any trouble

4

Simple installation

Because the capacitor is a relatively simple part, the installation just takes a few minutes and will save you at least a hundred bucks in labor

Feature

https://m.media-amazon.com/images/S/aplus-media-library-service-media/82820521-7d63-484c-b29a-db6dfe3536ab.__CR0,0,2928,1200_PT0_SX1464_V1___.jpg
  • "108-130 µF" in a motor run capacitor spec means it has a capacitance range of 108 to 130 microfarads (µF), determining its ability to store electrical energy. This range should match the motor's requirements for optimal operation.

  • Start capacitors give a large capacitance value necessary for a motor to start for a very short period of time (usually seconds long). A start capacitor can never be used as a run capacitor because it cannot handle current continuously.

  • There might be several reasons for this such as: Incorrect installation, faulty motor, capacitor compatibility or other electrical issues. If the issue persists, please don't hesitate to reach out. We're here to help.

  • No. The voltage rating of a capacitor indicates the maximum voltage that it can handle safely. If you put a 110-120 capacitor where a 220V is required, it may start the motor a couple of times but will fail very soon.

  • Capacitors are typically not designed for repair and are considered disposable components. We recommend you to replace by a new one.

Let's compare and discover the best choice!

https://m.media-amazon.com/images/S/aplus-media-library-service-media/af4b9ef2-dd5c-4875-98ae-1d71f2e91151.__CR0,0,1000,1125_PT0_SX200_V1___.png

108-130 uf 220-250 VAC

https://m.media-amazon.com/images/S/aplus-media-library-service-media/91e175e5-1a50-4fe1-a057-43c0da87bac8.__CR0,0,1000,1125_PT0_SX200_V1___.png

50 uf ± 5% MFD 370/440 V

https://m.media-amazon.com/images/S/aplus-media-library-service-media/f52cb5d6-0c65-4430-8926-5922bc7ddab3.__CR0,0,1000,1125_PT0_SX200_V1___.png

45+5 uf 370/440 VAC

https://m.media-amazon.com/images/S/aplus-media-library-service-media/3c4e955c-fc23-4e69-9c43-771f3d15ff1f.__CR0,0,1000,1125_PT0_SX200_V1___.png

7.5 uf 370/440 VAC

https://m.media-amazon.com/images/S/aplus-media-library-service-media/0b060bd7-fbee-4767-8360-3b6eb95246fe.__CR0,0,1000,1125_PT0_SX200_V1___.png

120uf 250V

https://m.media-amazon.com/images/S/aplus-media-library-service-media/f54e37d2-e273-494f-bf59-75b598b04722.__CR0,0,1000,1125_PT0_SX200_V1___.png

189-227 uf 220-250 VAC

Customer Reviews
Price
µF
108-130 50 45+5 7.5 120 189-227
Voltage
220-250 370/440 370/440 370/440 250 220-250
Shell's material
Plastic Metal Metal Metal Plastic Plastic
Type
Motor Start Capacitor Run Start Capacitor Run Start Capacitor Run Start Capacitor Motor Run Capacitor Motor Start Capacitor
Operating Temperature
-40°C to 65°C/-40°F to 149°F -25°C to 70°C/ -13°F to 158°F -25°C to 70°C/ -13°F to 158°F -25°C to 70°C/ -13°F to 158°F -25°C to 70°C/ -13°F to 158°F -40°C to 65°C/-40°F to 149°F
Operating Frequency
50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
CE & UL Certificate
? ? ? ? ? ?
1

Perfect fit

Universal fit with any brands with the same ratings

2

Premium quality

This product adopts a high-quality metalized polypropylene film that provides stable and durable performance

3

Saving solution

Enjoy the great feeling when your engine is repaired and works properly like before - BlueStars brings DIY solutions to help you deal with any trouble

4

Simple installation

Because the capacitor is a relatively simple part, the installation just takes a few minutes and will save you at least a hundred bucks in labor

  • "108-130 µF" in a motor run capacitor spec means it has a capacitance range of 108 to 130 microfarads (µF), determining its ability to store electrical energy. This range should match the motor's requirements for optimal operation.

  • Start capacitors give a large capacitance value necessary for a motor to start for a very short period of time (usually seconds long). A start capacitor can never be used as a run capacitor because it cannot handle current continuously.

  • There might be several reasons for this such as: Incorrect installation, faulty motor, capacitor compatibility or other electrical issues. If the issue persists, please don't hesitate to reach out. We're here to help.

  • No. The voltage rating of a capacitor indicates the maximum voltage that it can handle safely. If you put a 110-120 capacitor where a 220V is required, it may start the motor a couple of times but will fail very soon.

  • Capacitors are typically not designed for repair and are considered disposable components. We recommend you to replace by a new one.

Let's compare and discover the best choice!

https://m.media-amazon.com/images/S/aplus-media-library-service-media/af4b9ef2-dd5c-4875-98ae-1d71f2e91151.__CR0,0,1000,1125_PT0_SX200_V1___.png

108-130 uf 220-250 VAC

https://m.media-amazon.com/images/S/aplus-media-library-service-media/91e175e5-1a50-4fe1-a057-43c0da87bac8.__CR0,0,1000,1125_PT0_SX200_V1___.png

50 uf ± 5% MFD 370/440 V

https://m.media-amazon.com/images/S/aplus-media-library-service-media/f52cb5d6-0c65-4430-8926-5922bc7ddab3.__CR0,0,1000,1125_PT0_SX200_V1___.png

45+5 uf 370/440 VAC

https://m.media-amazon.com/images/S/aplus-media-library-service-media/3c4e955c-fc23-4e69-9c43-771f3d15ff1f.__CR0,0,1000,1125_PT0_SX200_V1___.png

7.5 uf 370/440 VAC

https://m.media-amazon.com/images/S/aplus-media-library-service-media/0b060bd7-fbee-4767-8360-3b6eb95246fe.__CR0,0,1000,1125_PT0_SX200_V1___.png

120uf 250V

https://m.media-amazon.com/images/S/aplus-media-library-service-media/f54e37d2-e273-494f-bf59-75b598b04722.__CR0,0,1000,1125_PT0_SX200_V1___.png

189-227 uf 220-250 VAC

Customer Reviews
Price
µF
108-130 50 45+5 7.5 120 189-227
Voltage
220-250 370/440 370/440 370/440 250 220-250
Shell's material
Plastic Metal Metal Metal Plastic Plastic
Type
Motor Start Capacitor Run Start Capacitor Run Start Capacitor Run Start Capacitor Motor Run Capacitor Motor Start Capacitor
Operating Temperature
-40°C to 65°C/-40°F to 149°F -25°C to 70°C/ -13°F to 158°F -25°C to 70°C/ -13°F to 158°F -25°C to 70°C/ -13°F to 158°F -25°C to 70°C/ -13°F to 158°F -40°C to 65°C/-40°F to 149°F
Operating Frequency
50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
CE & UL Certificate
? ? ? ? ? ?